SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2018-11464

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3).

LOW 3.7EPSS 1.86%

Does this matter?

Lower severity and a low EPSS score (1.86%). Track it; it rarely justifies an emergency change on its own.

Description

A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS 3.0
3.7 LOWCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
EPSS
1.86% probability · 78th percentile
CISA KEV
Not listed
Weakness
CWE-248
Affected
siemens/sinumerik 828d firmware · siemens/sinumerik 840d sl firmware
Source
productcert@siemens.com

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.