CVE-2018-11448
A vulnerability has been identified in SCALANCE M875 (All versions).
Does this matter?
Lower severity and a low EPSS score (0.32%). Track it; it rarely justifies an emergency change on its own.
Description
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a stored Cross-Site Scripting (XSS) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires that the attacker has access to the web interface of an affected device. The attacker must be authenticated as administrative user on the web interface. Afterwards, a legitimate user must access the web interface. A successful attack could allow an attacker to execute malicious code in the browser of a legitimate user. At the time of advisory publication no public exploitation of this security vulnerability was known.
- CVSS 3.0
- 4.8 MEDIUMCVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
- EPSS
- 0.32% probability · 25th percentile
- CISA KEV
- Not listed
- Weakness
- CWE-352, CWE-79
- Affected
- siemens/scalance m875 firmware
- Source
- productcert@siemens.com
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdfThird Party Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdfThird Party Advisory
Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.