SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367.

HIGH 8.2EPSS 2.90%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (2.90%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.

CVSS 3.0
8.2 HIGHCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
EPSS
2.90% probability · 86th percentile
CISA KEV
Not listed
Weakness
CWE-611
Affected
siemens/simatic pcs7 · siemens/wincc · ocpfoundation/local discovery server · ocpfoundation/ua .net
Source
cve@mitre.org

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.