SOC status:Duty analyst on shift

UK Cyber Defence
VulnerabilityModified

CVE-2007-4827

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus…

HIGH 7.5EPSS 4.73%

Does this matter?

High impact if exploited, but EPSS currently rates exploitation as unlikely (4.73%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit.

Description

Unspecified vulnerability in the Modbus/TCP Diagnostic function in MiniHMI.exe for the Automated Solutions Modbus Slave ActiveX Control before 1.5 allows remote attackers to corrupt the heap and possibly execute arbitrary code via malformed Modbus requests to TCP port 502.

CVSS 2.0
7.5 HIGHAV:N/AC:L/Au:N/C:P/I:P/A:P
EPSS
4.73% probability · 91th percentile
CISA KEV
Not listed
Weakness
CWE-119
Affected
automated solutions/modbus slave activex control
Source
cve@mitre.org

Source: NVD record, EPSS from FIRST.org, KEV from CISA. Refreshed daily.