{"id":"CVE-2018-8861","url":"https://www.cyber-defence.io/tools/cve/CVE-2018-8861","generatedAt":"2026-10-29T02:04:24.980Z","title":"Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a…","description":"Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system.","published":"2018-05-04T17:29:01.000Z","lastModified":"2026-06-17T02:05:32.000Z","status":"Modified","sourceIdentifier":"ics-cert@hq.dhs.gov","cvss":{"version":"3.0","score":8.7,"severity":"HIGH","vector":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L"},"cwe":["CWE-668"],"affected":["philips/brilliance firmware 64","philips/brilliance ict sp firmware","philips/brilliance ict firmware","philips/ brilliance ct big bore firmware"],"epss":{"score":0.00398,"percentile":0.33815,"date":"2026-10-27","history":[]},"kev":{"listed":false},"exploits":{"count":0,"verified":false,"firstPublished":null,"source":"Exploit-DB (https://gitlab.com/exploit-database/exploitdb)","entries":[]},"verdict":{"level":"high","text":"High impact if exploited, but EPSS currently rates exploitation as unlikely (0.40%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit."},"changes":[],"references":[{"url":"http://www.securityfocus.com/bid/104088","tags":["Third Party Advisory","VDB Entry"],"source":"ics-cert@hq.dhs.gov"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-123-01","tags":["Third Party Advisory","US Government Resource"],"source":"ics-cert@hq.dhs.gov"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["Vendor Advisory"],"source":"ics-cert@hq.dhs.gov"},{"url":"http://www.securityfocus.com/bid/104088","tags":["Third Party Advisory","VDB Entry"],"source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-123-01","tags":["Third Party Advisory","US Government Resource"],"source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["Vendor Advisory"],"source":"af854a3a-2127-422b-91ae-364da2661108"}],"sources":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-8861","epss":"https://www.first.org/epss/","kev":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","exploitdb":"https://www.exploit-db.com/"},"licence":"CC BY 4.0 — link back to the CVE Explorer if you publish the results; upstream data remains subject to its own terms."}