{"id":"CVE-2018-14787","url":"https://www.cyber-defence.io/tools/cve/CVE-2018-14787","generatedAt":"2026-10-28T21:20:06.605Z","title":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions,…","description":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions.","published":"2018-08-22T18:29:00.000Z","lastModified":"2026-06-17T01:41:38.000Z","status":"Modified","sourceIdentifier":"ics-cert@hq.dhs.gov","cvss":{"version":"3.1","score":7.8,"severity":"HIGH","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"},"cwe":["CWE-269"],"affected":["philips/intellispace cardiovascular","philips/xcelera"],"epss":{"score":0.0039,"percentile":0.33006,"date":"2026-10-27","history":[]},"kev":{"listed":false},"exploits":{"count":0,"verified":false,"firstPublished":null,"source":"Exploit-DB (https://gitlab.com/exploit-database/exploitdb)","entries":[]},"verdict":{"level":"high","text":"High impact if exploited, but EPSS currently rates exploitation as unlikely (0.39%). Schedule it in the normal patch cycle and watch for a rise in EPSS or a public exploit."},"changes":[],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01","tags":["Third Party Advisory","US Government Resource"],"source":"ics-cert@hq.dhs.gov"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["Vendor Advisory"],"source":"ics-cert@hq.dhs.gov"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01","tags":["Third Party Advisory","US Government Resource"],"source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["Vendor Advisory"],"source":"af854a3a-2127-422b-91ae-364da2661108"}],"sources":{"nvd":"https://nvd.nist.gov/vuln/detail/CVE-2018-14787","epss":"https://www.first.org/epss/","kev":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog","exploitdb":"https://www.exploit-db.com/"},"licence":"CC BY 4.0 — link back to the CVE Explorer if you publish the results; upstream data remains subject to its own terms."}